The installation is as follows.
1. Installation Steps
valve location into consideration;
a) Sensor stays away from mechanical vibration source, for example, pump. Use flexible
pipe to connect meter with pipeline if inevitable. The housing of meter must be standalone,
out of touch with any other device. There must be 3 times the size of sensor between 2
sensors if there are many flow meters on the same pipeline, to avoid resonance.
b) Do not install sensor on pipeline that easily expands with hot and contracts with cold,
especially near expansion joint, which leads to a worse stability.
c) Sensor stays away from industrial electromagnetic field, such as large generator and
transformer, better 5m at least. Such device influences the performance of drive coil and
pickoffs. Make sure magnetic field intensity less than 400A/m.
d) Sensor shall be installed on lower pipeline, to be easily full of fluid.
f) Build a sunshade if the meter is under direct solar radiation.
g) Keep the meter from corrosive liquid.
Gas Mass Flow Meter, Gas Mass Flowmeter, Gas Flow Meter, Gas Flowmeter, Gas Meter Zhejiang Sealand Technology Co., Ltd. , https://www.sealandflowmeter.com
a) Choose correct installation site, taking installation area, pipeline, transmitter location &
b) Install the meter according to direction mark on sensor;
c) Install the sensor & transmitter on pipeline;
d) Connect transmitter & sensor with 9-pin cable;
e) Start.
e) Make sure Ex-mark meet application requirements if in hazardous area.
IHF Fluoroplastic Lined Centrifugal Pump Features
IHF fluorine plastic lined centrifugal pump designed according to international standards, which is characterized by corrosion-resistant wear-resistant sealing superior and reliable. What is the characteristic of the machine seal? IHF Fluoroplastic Lined Centrifugal Pump Machine Seal Features The IHF Fluoroplastic Centrifugal Pump adopts the most advanced mechanical seal of external bellows with multi-layer protection to extend the machine Seal service life, increase the sealing performance, truly "drip leak"; for the delivery of impurities containing media, can be equipped with non-cooling water on the hard particle machine seal, for the delivery of "fluoride ion" media should be used "no Pressure sintering silicon carbide "material, so the user selection should take into account the media composition and the solid content. Further reading: China Construction Water Expo Guangzhou Ring Industry Leaders Industry Link (Xiamen) Technology Co., Ltd. Asia Pump Network Editor: He Daohui (QQ / WeChat:) http://beng.liuti.cn/ (Service Hotline: 400 -6030-811)
2. Site selection