Dry goods! Dalan Motor shared 79 knowledge of hydraulic motor operation and maintenance, and quickly collected!


In the daily management of electrical machines, the most common is our electric motor. The motor is the motive part of the machine. If there is a problem, it is a big problem. It is the most important part of the enterprise management, so the big blue motor is small. I would like to talk to you about the necessary knowledge of hydraulic motor operation and maintenance.

1. The generator stator voltage should not be greater than the rated voltage (110%). The minimum voltage should not be lower than the rated voltage (90%) and should meet the (factory) voltage requirements.

2. The normal running frequency of the generator should be kept at (50) Hz, the allowable variation range is (±0.2) Hz, and it can be continuously operated according to the rated capacity. When the frequency changes, the stator current, excitation current and temperature of each part shall not exceed (rated value).

3. The generator stator voltage is allowed to fluctuate within the rated value range (±5%). When the power factor is rated, its rated capacity does not change, that is, when the stator voltage fluctuates within this range, the stator current can be changed proportionally. . However, when the generator voltage is lower than the rated value (95%;), the long-term allowable value of the stator current shall not exceed the rated value (105%.).

4. The hydrogen purity of the generator operation shall not be less than (96%) and the oxygen content shall be less than (2%).

5. The rated power factor of the generator is (0.85). Generators that have not been subjected to the phase-in-phase test, when the excitation regulator device is automatically activated, the power factor is allowed to operate for a long period of time in the range of 0.96 to 1; when the power factor is changed, the power factor should be The power of the power does not exceed the range of the (PQ) output curve at the time of hydrogen pressure.

6. After the generator is juxtaposed, the active load increase speed is determined by (turbine), and the reactive load increases speed (not limited), but the stator voltage change should be monitored.

7. The insulation resistance of the generator rotor winding is measured with a (500V) shaker. The insulation value must not be less than (0.5MΩ).

8. When the stator three-phase current is unbalanced, a (negative sequence) current will be generated.

9. During the boosting process, the generator checks that the three-phase voltage of the stator should rise (smoothly) and the rotor current should not exceed (no-load value).

10. 6KV motor measurement insulation should be measured using a (2500 V) volt table, and the measured insulation resistance should be greater than (6) MΩ.

11. Under normal conditions, the motor of the squirrel cage rotor is allowed to start in the cold state (2 times), and each time interval is not less than (5) minutes, allowing to start (1) times in the hot state, only in the accident Motors that have been processed or started for less than (2 to 3) seconds can be started more often.

12. The insulation resistance of the 6KV high-voltage factory motor is measured under the same environment and temperature. If the current measurement is lower than (1/3~1/5) times of the previous measurement value, the cause should be checked and must be measured. The absorption ratio is "R60/R15", which should be greater than (1.3).

13. The motor can be operated within the rated voltage and the power frequency (±l%), and its rated output does not change.

14. The main transformer cooler (full stop) is allowed to run at the lower limit of the rated load. If the load is small, the main transformer upper oil temperature does not reach the specified value, it is allowed to rise to the specified value, but the longest running time of the main transformer must not exceed (60). )minute.

15. The three-phase unbalanced current of the three-phase AC motor must not exceed (10%) of the rated value, and the current of any one phase must not exceed (rated value).

16. For oil-immersed self-cooling and oil-immersed air-cooled transformers, the maximum allowable oil temperature of the upper layer shall not exceed (95) °C, and generally should not exceed (85) °C.

17. When the gas protection secondary circuit is grounded at one point, the heavy gas protection should be changed to the (signal) position.

18. The oil temperature of the upper layer of the transformer that forces the oil circulation to be air-cooled generally does not exceed (75) °C, and the maximum does not exceed (85) °C.

19. The applied voltage of the transformer shall not exceed (105%) of the rated value of the tap. At this time, the secondary side of the transformer may have a rated current.

20. The general power plant adopts double busbar wiring. During normal operation, one component (grounding) should be guaranteed on each entry line. The main transformer is generally grounded (grounded blade), and the neutral point is normally (directly) grounded.

21. 6KV switchgears are equipped with “five-proof” mechanical locking devices. Generally, the locking function of the forced mechanical locking device is (the trolley switch cannot be moved when it is closed), (the grounding knife is closed when the car is closed) The switch cannot be pushed into the working position), (the switch cannot be closed when the switch is in the working position), (the grounding knife does not close, and the rear panel of the switchgear cannot be opened).

22. After all the isolating switches are closed, the contact (three-phase contacts) must be in good contact.

23. Before closing the grounding switch, make sure that the power switch on each side is in the (disconnected) position and after the verification (no voltage).

24. In the event of a load broach lock, it should be quickly (closed) before the arc is broken. If the arc is broken, it is forbidden to close it again. If the load is closed, it is forbidden to restart (disconnect).

25. When there is no switch in the circuit, the isolation switch can be used to perform loop equalization current with the pull-in voltage not exceeding 10KV and the current below (70A).

26. The normal operating voltage of the cable line should not exceed (15%) of the rated voltage of the cable.

27. Under normal circumstances, electrical equipment is not allowed to operate (no protection). If necessary, partial protection can be deactivated, but (main protection) is not allowed to be deactivated at the same time; it is forbidden to open the protection cabinet door during operation, and it is forbidden to continue in the centralized control room. Guaranteed indoor use (wireless) communication equipment.

28. Insulation resistance is measured by a (500) V shaker for AC and DC low voltage factory motors below 380V. The insulation resistance of the motor must not be less than (0.5) MΩ.

29. Generator definite time overload protection reflects the size of the generator (stator current).

30. The overvoltage protection of the generator stator winding reflects the magnitude of the (terminal voltage).

31. Generator Timing The negative sequence overcurrent protection reflects the size of the generator stator (negative sequence current) and prevents the generator (rotor surface) from overheating.

32. The four limiting factors on the PQ curve of the generator are (heating of the stator windings, heating of the rotor windings, heating of the stator cores, stable operating limits).

33. Generator reverse power protection for protection (turbine).

34. The order of installing the grounding wire is first (ground) and rear (conductor).

35. Electrical insulation is graded according to the maximum work (temperature) allowed in normal operation.

36. The current value indicated by the AC ammeter indicates the (effective) value of the current.

37. The safety distance of equipment without power failure is (0.7)m for 6kV, (1.5)m for 110KV, and (5)m for 500KV.

38. In power plants, the phase sequence of the three-phase busbars is represented by a fixed color. The specified phases (yellow), (green), and (red) indicate phase A, phase B, and phase C, respectively.

39. The equipment ground voltage is below (250) volts for low voltage equipment, so we often say that the 380V plant power system is (low voltage equipment).

40. When the generator is in normal operation, the three-phase unbalance value of the stator current generally cannot exceed (10%) of the stator rating.

41. The operation of phase differential high frequency protection uses a (high frequency) signal to compare the current (phase) across the protected line.

42. When the isolating switch is found to be hot, reduce the equipment (load) until it does not heat up, and strengthen the ventilation and cooling at that place. If the heat is serious, stop the equipment after it is running.

43. When the temperature difference between the highest and lowest temperatures between the stator bars of the water-cooled generator is (8) °C or the temperature difference of the stator bar water pipe is (8) °C, the alarm should be reported and the cause should be ascertained. Reduce load) processing.

44. The temperature difference between the stator bars of the water-cooled generator is (14) °C or the temperature difference of the stator inlet pipe is (12) °C, or the temperature of the temperature measuring element in any stator slot exceeds (90) °C or the outlet temperature exceeds ( 85) At °C, after confirming that the temperature measuring component is correct, in order to avoid a major accident, it should be immediately (stopped), (backwashing) and related inspection processing.

45. The product of the rms value of the total voltage in the sinusoidal AC circuit and the rms value of the current, both (active power) and (reactive power), we call it (apparent power).

46. ​​In a circuit, the current flowing into the node (equal to) the current flowing from the node, which is Kirchhoff.

47. Starting from any point in the loop, one cycle along the loop, the sum of the potential rises (equal to) the sum of the potential drops, which is Kirchhoff (second law).

48. In the various methods of calculating complex circuits, the (branch current) method is the most basic method.

49. In an (inductive) circuit, the voltage leads the current; in a (capacitive) circuit, the voltage lags the current.

50. In power systems, shunt reactors are commonly used to absorb excess (reactive) power and reduce (system voltage).

51. In a three-phase AC circuit, a delta-connected power supply or load, their line voltage (equal to) phase voltage.

52. The total power of a symmetrical three-phase AC circuit is equal to (3) times the single-phase power.

53. For a symmetrical three-phase AC circuit, the neutral point voltage is equal to (zero).

54. In a power system, a short circuit is an abnormal connection between (phase and phase) or (phase to ground) through an electric arc or other lesser impedance.

55. A battery is an energy storage device that converts (electrical) energy into (chemical) energy storage; in use, it converts (chemical) energy into (electrical energy) and is released through an external circuit.

56. The size of the conductor resistance is related not only to the (length) and (cross-sectional area) of the conductor, but also to the (material) and temperature of the conductor.

57. In a closed circuit, the voltage is a condition that generates a current. The magnitude of the current is related to both the (resistance) and the (terminal voltage) magnitude of the circuit.

58. In a series circuit, the voltage distribution across the load is proportional to the magnitude of each load resistor; in a parallel circuit, the current distribution of each branch is inversely proportional to the resistance of each branch.

59. When the (current) in the coil changes, the (self-inductance) electromotive force is generated at both ends of the coil.

60. After the conductor is energized, the direction of the electromagnetic force received in the magnetic field is determined by (left-hand rule), and the direction of the induced electromotive force is determined by the right-hand rule when the conductor makes a cutting magnetic field motion in the magnetic field.

61. The number of periodic changes in alternating current per second is called (frequency), indicated by the letter (f), the unit name is (hertz), and the unit symbol is expressed in (Hz).

62. The maximum instantaneous value of a sinusoidal alternating current in a cycle is called the (maximum) value of the alternating current, also known as (amplitude) or (peak).

63. The maximum value of the rms value of the alternating current is divided by (√2).

64. In a circuit composed of resistors, inductors, and capacitors, only (resistive) components consume electrical energy, while (inductive) components and (capacitor) components are energy-exchanged and do not consume electrical energy.

65. The power supply of the star connection not drawn at the neutral point is (three-phase three-wire), and the current relationship is that the line current is equal to (phase current).

66. The greater the current through a coil, the stronger the (magnetic field) produced, and the more (magnetic) lines that pass through the coil.

67. The current-carrying coil can generate a magnetic field, and its (strong) is proportional to the magnitude of the current through the current-carrying conductor.

68. The voltage between the three-phase end lines is called (line voltage); the voltage between the end line and the neutral point is (phase voltage); in a symmetrical circuit with a star connection, the line voltage is equal to (√3) times the phase Voltage.

69. The main cause of short-circuit in the power system is the destruction of the (insulation) of the current-carrying part of the electrical equipment.

70. Short-circuit damage to electrical equipment mainly includes: (1) current (thermal effect) causes equipment to burn or damage insulation; (2) (electric power) causes electrical equipment to be deformed and destroyed.

71. Electrical equipment and current-carrying conductors must have sufficient (mechanical) strength to withstand the electrodynamic effects of short circuits and adequate thermal (stability).

72. The transformer is based on the principle of (electromagnetic induction), which converts the voltage and current of an alternating current into voltages and currents of the same (frequency) but different (values).

73. The principle of induction motor is that when three-phase is set in the winding, a three-phase symmetrical alternating current flows, and a (rotating) magnetic field is generated. The magnetic field line of the magnetic field cuts the wire on the rotor to induce (current). Because the stator magnetic field interacts with the rotor current, Produce electromagnetic (torque) and turn it up.

74. Both the copper wire and the aluminum wire are connected by a conversion joint. If they are directly connected, the copper and aluminum wires have a potential difference. If there is moisture in the joint, it will form an (ionization) effect and cause electrical corrosion.

75. In the vicinity of the transmission line, if an insulator is placed, an (inductive) charge is generated. This phenomenon is called (electrostatic) induction of the transmission line.

76. Sulfur hexafluoride (SF6) is a (colorless), (odorless) non-combustible gas with very stable properties.

77. The battery is used as a (control) and (protected) DC power supply in the power plant, which has the advantages of stable voltage and reliable power supply.

78. The active material on the (positive) plate of the battery is lead dioxide, and the active material on the (negative) plate is spongy lead.

79. The capacity of a group of batteries is 1200AH. If it is discharged at a current of 100A, the continuous power supply time is (12 hours).




----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant

Copyright http: / (Dalan Motor) Reprint, please indicate the source
Http://news.chinawj.com.cn

Kitchen Sink Mixer

Kitchen sink mixer
Kitchen sink mixer is suitable for all kinds of kitchen sinks, single hole deck mounted installation, outlet water pipe can be rotated 360°. Main body use A Class H59 brass gravity casting. The surface finished by 8 - 12μm thickness electro plating, bright and corrosion resistance. Two pieces of 40cm flexible hose include in kitchen sink mixer package.